Change list

Selenium lib hardcodes the graceful shutdown timeout to 2 seconds (zero on Windows). This is not enough for Appium to properly shutdown all the drivers and clean up the leftovers.

Types of changes

  • No changes in production code.
  • Bugfix (non-breaking change which fixes an issue)
  • New feature (non-breaking change which adds functionality)
  • Breaking change (fix or feature that would cause existing functionality to not work as expected)


// This all magic is necessary, because Selenium does not publicly expose
// process killing timeouts. By default a process is killed forcibly if
// it does not exit after two seconds, which is in most cases not enough for
Copy link
Member

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

a process is killed forcibly if it does not exist after two seconds

Interesting.

@mykola-mokhnach mykola-mokhnach merged commit d1d0f78 into appium:master May 27, 2020
@mykola-mokhnach mykola-mokhnach deleted the service_kill branch May 27, 2020 11:33